Pengaruh Modifikasi Pipa Pendingin Terhadap Efektivitas Induced Draft Cooling Tower LBC-50

  • Muhammad Fairuz Naufal Sekolah Tinggi Teknologi Wastukancana
  • amri abdulah Sekolah Tinggi Teknologi Wastukancana
  • Yadi Heryadi Sekolah Tinggi Teknologi Wastukancana
  • Apang Djafar Shieddieque Sekolah Tinggi Teknologi Wastukancana
  • Dede Ardi Rajab Sekolah Tinggi Teknologi Wastukancana
  • Sri Suhartini Sekolah Tinggi Teknologi Wastukancana
Keywords: induced draft cooling tower; piping line modification; effectiveness; cooling capacity; head loss.

Abstract

This study aims to analyze the performance enhancement of an induced draft cooling tower through modifications to the water distribution piping line, as well as to evaluate the thermal and hydraulic performance before and after modification. The initial system exhibited relatively low cooling effectiveness due to uneven water distribution and limited heat transfer between air and water within the tower. Therefore, the piping layout was redesigned to improve flow uniformity, enlarge the air–water contact area, and minimize heat losses, thereby enhancing overall cooling efficiency. The experimental tests were conducted under identical operating conditions with an inlet water temperature of 38 °C. The results showed that the outlet water temperature decreased from 33.78 °C (before modification) to 28.95 °C (after modification). The range increased from 5.17 °C to 9.12 °C, while the approach decreased from 4.68 °C to 2.61 °C, indicating a more effective cooling process approaching ideal conditions. Furthermore, the cooling capacity showed a substantial increase from 21,717.4 kW to 61,515.1 kW, signifying that the modified cooling tower can dissipate a greater amount of heat and support higher cooling demands in industrial operations. In addition, the system effectiveness improved from 52.45% to 77.58%, demonstrating a significant enhancement in heat transfer efficiency as a result of improved fluid distribution. On the other hand, the total head loss increased from 39.11 m to 63.71 m, indicating higher flow resistance due to the new configuration, but it remained within acceptable limits. Overall, the study concludes that modifying the piping line in the induced draft cooling tower significantly improves thermal performance, cooling effectiveness, and capacity, making the redesigned configuration a viable approach to increase the efficiency of large-scale industrial cooling systems..

References

J.C. Hensley, Cooling Tower Fundamentals, Overland Park, Kansas, 2009.

P. Navarro, J. Ruiz, A.S. Kaiser, M. Lucas, Effect of fill length and distribution system on the thermal performance of an inverted cooling tower, Appl Therm Eng 231 (2023) 120876. https://doi.org/10.1016/J.APPLTHERMALENG.2023.120876.

S.C. Kranc, The Effect of Nonimiform Water Distribution on Cooling Tower Performance, Journal of Energy 7 (1983) 636–639. https://doi.org/10.2514/3.62710.

Y. Zhou, Q. Li, Z. Wang, S. Li, F. Wei, J. Liu, D. Yu, Thermal performance model of cooling towers for operational optimization: An equivalent temperature difference coefficient-based approach, Appl Therm Eng 252 (2024) 123595. https://doi.org/10.1016/J.APPLTHERMALENG.2024.123595.

Z. Li, H. Wei, T. Wu, X. Du, Optimization for circulating cooling water distribution of indirect dry cooling system in a thermal power plant under crosswind condition with evolution strategies algorithm, Energies (Basel) 14 (2021). https://doi.org/10.3390/en14041167.

Y.A.. Çengel, A.J.. Ghajar, Heat and mass transfer : fundamentals & applications, Fifth Edition, McGraw Hill Education, New York, 2015.

M.A. Irawan, H. Ahyadi, ANALISIS TEMPERATUR LINGKUNGAN TERHADAP KINERJA COOLING TOWER TIPE INDUCED DRAFT UNIT 2 PADA PT. X, 2020.

H. Alkindi, H. Santosa, E. Sutoyo, ANALISIS HEAD LOSSES PADA CIRCULATING FLUIDA AIR DALAM DUA JENIS PIPA, 2023.

Published
2025-11-30
How to Cite
Naufal, M. F., abdulah, amri, Heryadi, Y., Shieddieque, A. D., Rajab, D. A., & Suhartini, S. (2025). Pengaruh Modifikasi Pipa Pendingin Terhadap Efektivitas Induced Draft Cooling Tower LBC-50. Jurnal Teknologika, 15(2), 817-826. https://doi.org/10.51132/teknologika.v15i2.540